HAZARD LAMP
The HL-95 Hazard Lamp is a semi-portable, free standing illuminated warning device CE marked to the ATEX directive for safe use in Zones 0, 1 or 2 Hazardous Areas.
Product Information
HL-95, HL-95MOD
ZONES: 0, 1 AND 2
The HL-95 is powered by an air-depolarised primary cell battery, which has an exceptionally high capacity from a relatively small, light weight package size. A single battery, used in the flashing light output mode, provides continuous duration for up to 1500 hours, or two months. In static mode where the lamp is continuously lit, the duration will be up to 500 hours. Operation of the lamp and selection of flashing or static mode is made from a single three position toggle switch mounted on the outside of the lamp. A further extension to battery duration can be achieved by selecting 'daylight cut-out mode' via the internally mounted selection switch. If the lamp is being used outdoors a light dependant resistor will detect when darkness falls and accordingly activate the lamp. Equally, when light levels increase, it automatically switch off, conserving battery energy. It is estimated that a lamp set to flashing and in daylight cut-out mode could operate for up to six months from a single battery.
The HL-95 has two lenses positioned 'back to back' with the light output from these lenses being greater than 2cd. Light is provided by a pair of 'everlasting' light emitting diodes. The use of such solid state devices allows the lamp to be sited in zone 0, 1 or 2 hazardous areas. The light emitting diodes are coloured amber and are positioned behind a transparent plastic lens. The lens is protected from damage by a stainless steel guard fitted directly to the impact resistant, static dissipative polypropylene lamp body.
NSN Codes
6120-99-7091078 - HL-95MOD
-
Long Battery Life
1500 hours in flashing mode
-
Hazardous Area Certified
Unique to Wolf
-
Simple Construction
Low maintenance
Features & Benefits
- Approved for safe use in Zones 0, 1 or 2
- Flashing or static output selectable
- Operation in flashing mode up to 2 months
- Daylight cut-out mode selectable
- Ultra-bright L.E.D. light source
- 180° bi-directional lens arrangement
- Highlighting obstacles in the Hazardous Area
- Effective demarcation of Hazardous Area zones
HL-95
Gas Zone: 0, 1 and 2
Power: Battery
HL-95MOD
Gas Zone: 0, 1 and 2
Power: Battery
Product Reference | HL-95 | |
---|---|---|
Product Description | Primary Battery Operated Safety Hazard Lamp | |
Code | II 1 G Ex ia op is IIC T4 Ga | |
Type of Protection | "i" intrinsic safety | |
Area of Classification (Gas) | Zones 0, 1 and 2, Gas Groups IIA, IIB and IIC |
|
Temp. Classification | T4 | |
Ambient Temperature | -10°C to +40°C | |
Certificate | BAS 99 ATEX 1044X | |
Enclosure | Static dissipative polypropylene with metal lens guard | |
Lens | Transparent plastic, colour as light source | |
Light Output | ≥ 2cd | |
Light Source: | Type | Solid State LED |
Colour | Amber | |
Power Source: | Part Number | HL-3155X |
Type | Air Depolarised Primary Cell Battery | |
Volts | 5.6v | |
Capacity | 40Ah | |
Weight | 1.7kg | |
Dimensions | L 110 x W 110 x H 140 mm | |
Light Duration | 1500 hours flashing mode, 500 hours static mode | |
Ingress Protection | IP21 | |
Weight (incl. battery) | 2.9kg |
- All information has been gathered under laboratory conditions, the user must regard the values given as approximate.
- Changes may be made to the above specification without notification, details are available on request.
Product Dimensions
Hazard Lamp Product Information Sheet
(PDF, 207 KB)
HL-15 Hazard Lamp Instructions
(PDF, 420 KB)
Hazard Lamp ATEX Certficate
(PDF, 177 KB)
Got a question?
Want to learn more? Just contact us and we’ll be more than happy to help!